THE ALARMALERT MODULE CAN BE SUPPLIED WITH A SIM CARD AND SENSORS ALL SET UP READY TO USE IF REQUIRED.


BASIC INSTALLATION GUIDE.



If a control panel is not used, connect a hidden ON/OFF switch or KEYSWITCH in series with one off the ORANGE wires to SET and UNSET the Alarmalert module.

Or the Alarmalert module can be set and unset by  TEXT  message from the center number only if remote relay contacts are used as on /off setting switch.


Connect RED WIRE TO 12v + supply.


Connect thick BLACK TO   12v - 0v supply.


Cut ORANGE LEAD ( or purple and black 4G VERSION )and connect both  wires to any NORMALLY OPEN alarm sensor, detector or microswitch.Connect any number of multiple sensors in parallel.


If used with an alarm control panel,connect a relay coil to the alarm or bell output and the relays N/O contacts to the ORANGE LEAD. 


Connect YELLOW to relay coil terminal 1 and 12v+ to coil terminal 2 ( ONLY NEEDED IF REMOTE CONTROL OF A RELAY IS BY TEXT MESSAGE IS REQUIRED)


Connect  MICROPHONE LEAD to the mic plug.


REST NOT USED.


THE SUPPLIED 12V RELAY CONNECTIONS ARE:


WHITE PIN 85 & YELLOW PIN 86  ARE RELAY 12V COIL.


GREEN PIN 30 & GREEN PIN 87 ARE NORMALLY OPEN CONTACTS    N/O

GREEN PIN 30 & GREEN PIN 87a ARE NORMALLY CLOSED CONTACTS N/C





BASIC SET UP. 


Check for good signal strength in the area of operation with a mobile phone and a 2G WITH 4 G network sim card.

Install any contract or PAYG  2G with 4G sim card that shows good signal and turn slide switch on.

Slow flashing red shows power and green GSM ok.

Continuous blue shows GPS coverage ok, only needed if tracking the Alarmalerts location.



SEND THE FOLLOWING TEXT MESSAGES TO THE SIM CARD NUMBER IN THE ALARMALERT MODULE.


SOS,A,number1,number2,number3#         to set up the 3 numbers to be called when activated.


If only one number needed send      SOS,A,the number#     eg         SOS,A,0123456789#


SOS,D, the number in figures#     to delete a number.



GPRSON,OFF#            GPRSON,0#     to disable gprs as not required.


PARAM#            to check the settings.


URL#                to get the exact GPS location of the Alarmalert module at at time.


The module will text back Ok if phone numbers are acepted and show if alarm is armed or dissarmed.


IF INCORRECT DATA IS SENT THE UNIT WILL NOT RESPOND.

TO RESET, SWITCH OFF AT SLIDE SWITCH, REMOVE SIM CARD AND START AGAIN AFTER 5 MINS.

NOTE:   INCLUDE ALL COMMA,S AND DO NOT LEAVE ANY SPACES.


To listen to the microphone ring the sim cards number from any of the SOS phone numbers.



ADVANCED SET UP.


SENALM,ON#    to activate the built in vibration sensor with time delays.


SENALM,OFF#   to deactivate the built in vibration sensor.


CENTER,A, phone number in figures#    to set up one number to activate the relay via text message, Eg  CENTER,A,0123456789#


CENTER,D#      to delete the CENTER number.


RELAY,1#   activates the remote relay providing module is not moving above 10mph.


RELAY,0#   deactivates the remote relay.


The Relay can only be activated and deactivated by the one mobile device which has been set as a CENTER number,the same device can also be set as a SOS number.